2 channels, 95 - 265V, for Smartline transducers and Analogline transducers with 0-10 V output, USB interface and RS232 interface

VD12S2

VD12 is an intelligent control unit for applications in apparatus and plant engineering or special equipment construction.
19inch cassette 14 HP x 3 RE.

It allows the simultaneous control of 2 measuring channels.

It can be combined with all Smartline™ and 0-10 V Analogline transducers.

Operating temperature +5…+50 °C
Storage temperature -20…+60 °C
Voltage supply 95 – 265 VAC, 50/60 Hz
Display LCD graphic display, 51×31 mm, background illumination, resolution 128×64,
Dimensions 25 × 18 × 16 cm
Protection class IP20
Weight (kg) 750g
Power consumption max. 25 W inclusive of transducer
Serial interface Mini-USB, Type B, 5pin, female, Virtual Com Port protocol, RS232: 3.5 mm jack, 3-pole
Switching output 2 x relay, change-over type, SP assignable (VD14S4: 2×2) Phoenix strip terminal 6-pin (VD14S4: 2x) lifetime > 300,000 cycles, 4 A / 250 VAC, 2 A / 45 VDC
Suitable vacuum gauge All Smartline transducers, Analogline Transducers: VSC43MV, VSP63MV, VSP64MV
Versions VD12S2, VD122P, VD124P, VD1253P, VD1263P, VD1277P, VD1288P
scanning rate 2 Hz (0,5 s)
Scanning Rate RS485: 12,5 Hz (80 ms) | 0-10V: 50 Hz (20 ms)
Messeingänge 1 x RS485, SubD, 15pin, male, for Smartline, VD12: 2 x 0 – 10V Amphenol C91E, 6pin, female, for Analogline
Category Vacuum controller
Serial interfaces RS232, USB