The EH mechanical booster pump, based on the simple Roots principle, remains the favourite pump for applications where high pumping speeds are required for pressures in the region of 0.01 to 10 mbar. This pump must always be backed by another pump, which can deliver against a high-pressure differential to atmospheric pressure.
Operating at relatively low pressures, the mechanical booster pump is not exposed to the same concentrations of corrosive process media as is the backing pump, which makes it highly reliable.
Technical data | |
Displacement (swept volume) | |
50Hz | 2590 m3h-1 / 1525 ft3min-1 |
60Hz | 3110 m3h-1 / 1830 ft3min-1 |
Effective pumping speed with backing pump | |
E2M175 | 1750 m3h-1 / 1031 ft3min-1 |
E2M275 | 1900 m3h-1 / 1119 ft3min-1 |
Pressure differential across pump | |
50Hz | 0-120 mbar / 0-90 Torr |
60Hz | 0-67 mbar / 0-50 Torr |
Inlet connection | ISO160 |
Outlet connection | ISO100 |
Rotational speed | |
50Hz | 0-2900 rpm |
60Hz | 0-3500 rpm |
Operating continuous inlet pressure | 0-1000 mbar / 0-760 Torr |
Maximum outlet pressure | 1000 mbar / 760 Torr |
Recommended backing pumps | GXS250, GXS450, E2M175, E2M275 |
Electrical supply | |
50Hz | 220-240V / 380-415V |
60Hz | 230V / 460V |
Motor power | |
Hydrocarbon | 11kW / 15hp |
PFPE | 11kW / 15hp |
ATEX | 11kW |
Explosion proof | 15hp |
Ambient temperature range | |
Operating | 5 to 40°C / 40 to 104°F |
Storage | -10 to 80°C / 14 to 176°F |
Maximum operating humidity | 90% RH |
Recommended oil | |
Standard version | Ultragrade 20 |
PFPE version | Fomblin® YVAC 16/6 |
Oil capacity | |
Gear case | 3.5 litre / |
Coupling cover | 6.5 litre |
Shaft seal reservoir | 1.5 litre |
Weight | 345 kg |