This range of high capacity mechanical booster pumps is designed to operate reliably for long periods with no need for maintenance. The HV pumps can be fitted with an inverter to allow them to be started at atmospheric pressure, at the same time as the dry pumps.
Technical data | |
Displacement | |
50 Hz | 30000 m3h-1 / 17660 ft3min-1 |
60 Hz | 36000 m3h-1 / 21200 ft3min-1 |
Maximum pressure differential | |
50 Hz | 24 mbar |
60 Hz | 29 mbar |
Recommended backing pumps | IDX1300 and HV8000 |
Maximum motor power | 55 kW / 75hp |
Ambient operating temperature | -20 to 40°C |
Cooling water supply | |
Maximum supply temperature | 30°C |
Maximum supply pressure | 5 bar / 73 psi |
Maximum operating humidity | 90% RH |
Weight (without motor) | 3017 kg |