            Stokes 6" series process isolation boosters are designed to be used in conjunction with rotary-piston, dry vacuum, rotary vane and liquid ring pumps to increase pumping speed at working pressures and shorten pump down time significantly.
| Technical data | |
| Displacement | |
| V belt (2750 rpm) | 3375m3h-1 / 2000ft3min-1 | 
| Direct drive (3000 rpm) | 3685m3h-1 / 2170ft3min-1 | 
| Direct drive (3600 rpm) | 4420m3h-1 / 2600ft3min-1 | 
| Inlet/outlet flanges | 8” ASA/ANSI flange | 
| Motor power EU/Asia | 11kW | 
| Motor power US TEFC | 15hp | 
| Cooling water | 7.6-11.4 l min-1 / 2-3 gal min-1 | 
| Oil capacity (horizontal flow) | 1.9 litre / 0.51gal | 
| Oil capacity (vertical flow) | 4.1 litre / 1.1gal | 
| Max pressure differential | 506mbar / 380Torr | 
| Max temp rise | 135°C / 275°F | 
| Max discharge temp | 191°C / 375°F | 
| Weight bare shaft | 234kg / 515lbs | 
| Weight TEFC direct drive | 397kg / 875lbs | 
| Recommended Oil | V- Lube H | 