Superblowers are designed to be used in conjunction with rotary-piston, liquid ring, rotary vane and dry vacuum pumps to increase pumping speed at working pressures and shorten pump down time significantly. The Superblower can be mounted separately or on the inlet of the backing pump to create a compact integrated package.
Horizontal flow | Vertical flow | |
Displacement V belt (2750 rpm) | 3375 m3h-1 / 2000 ft3min-1 | 3375 m3h-1 / 2000 ft3min-1 |
Displacement direct drive (1800 rpm) | 2210 m3h-1 / 1300 ft3min-1 | 2210 m3h-1 / 1300 ft3min-1 |
Displacement direct drive (3000 rpm) | 3685 m3h-1 / 2170 ft3min-1 | 3685 m3h-1 / 1170 ft3min-1 |
Displacement direct drive (3600 rpm) | 4420 m3h-1 / 2600 ft3min-1 | 4420 m3h-1 / 2600 ft3min-1 |
Inlet/outlet flanges | 8” ASA/ANSI flange | 8” ASA/ANSI flange |
Motor option US TEFC | 10 hp | 10 hp |
By-pass available | No | No |
Cooling water | No | No |
Oil capacity | 1.9 liter / 0.51 gal | 4.1 liter / 1.1 gal |
Max pressure differential | 506 mbar / 380 Torr | 506 mbar / 380 Torr |
Max temp rise | 135°C / 275°F | 135°C / 275°F |
Max discharge temp | 191°C / 375°F | 191°C / 375°F |
Foot print TEFC direct drive (L x W x H) | 1391 x 406 x 543 mm | 1391 x 543 x 406 mm |
54.75 x 16 x 21.4 in | 54.75 x 21.4 x 16 in | |
Weight TEFC direct drive | 390 kg / 860 lbs | 390 kg / 860 lbs |